The high temperature thermostats of the USH 400 line, with controlled cooling MVH (option), are specially designed for external systems at high temperatures up to 400 °C. The controlled cooling MVH enables controlled refrigeration at every temperature, for instance; when exothermal reactions occur. A further highlight is the efficient pump with a terrific 0.8 bar hood pressure.
| Technical features | Units | USH 400 | USH 400/6 |
|---|---|---|---|
| Working temperature range | °C | 80...400 | 80...400 |
| Temperature range with MVH | °C | 20...400 | 20...400 |
| Display resolution | °C | 0.01 | 0.01 |
| Temperature stability | ± °C | 0.02...0.1 | 0.02...0.2 |
| Heating capacity | °C | 3.0 | 5.6 |
| Surface loading of the heater | W/ cm² | ca. 3 | ca. 5.6 |
| Cooling capacity with MVH (cold water temperature 10°C) | kW | 6 at 300°C, 2 at 100°C | |
| Cool water flow / pressure for MVH | L/ min / bar | ca. 10 / 0.5...6 | |
| Pump pressure max. | bar | 0.80 | 0.80 |
| Pump flow (pressure) max. | L/ min | 22 | 22 |
| Bath volume / with additional expansion vessel (1.2L) | L | 1.9 / 2.1 | 1.9 / 2.1 |
| Expansion volume / with additional expansion vessel (1.2L) | L | 0.9 / 2.2 | 0.9 / 2.2 |
| Loading | kW | 3.2 | 5.8 |
| 230V; 50Hz | |||
| 230V; 60Hz | |||
| 400V; 3/N/PE; ~ 50Hz | |||
| 440...480V; 3/N/PE; ~ 60Hz | |||